| Digital Radiography Brochures: | Active Area | Pixel Size | Active Matrix | Fill Factor | Frame Rate | Zoom | Maximum Energy |
|---|---|---|---|---|---|---|---|
| Click on links to access data sheets. | |||||||
| PaxScan 1313 | 13x13 cm (5.1x5.1 in) | 127 µm | 1024 x 1024 | 57% | 10 FPS @1x1 30FPS @2x2 | Yes | 160 Kv (225 kV w/opt shield) |
| PaxScan 2020 | 20x20 cm (8x8 in) | 194 µm | 1024 x 1024 | 70% | 30FPS@ 1x1 60FPS@ 2x2 | No | 150 Kv |
| PaxScan 2520E+ | 25x20cm (10x8 in) | 127 µm | 1920 x 1536 | 57% | 1FPS@ 1x1 | Yes | 150 Kv |
| PaxScan 2520V | 25x20cm (10x8 in) | 127 µm | 1920 x 1536 | 57% | 10FPS@ 1x1 30FPS@ 2x2 | Yes | 160 Kv (225 kV w/opt shield) |
| PaxScan 4030E | 40x30 cm (16x11.5 in) | 127 µm | 3200 x 2304 | 57% | 1FPS@ 1x1 | No | 150 Kv |
| PaxScan 4030CB | 40x30 cm (15.7x11.8 in) | 194 µm | 2048 x 1536 | 70% | 7.5FPS@ 1x1 30FPS@ 2x2 | Yes | 150kV |
| PaxScan 4336R | 43x36 cm (17x14 in) | 139 µm | 3072 x 2560 | 100% | 6/8 sec | No | 150 kV |
| PaxScan 4343R | 43x43 cm (17x17 in) | 139 µm | 3072 x 3072 | 100% | 6/8 sec | No | 150kV |
|
|
|
|
The PaxScan® 1313 interfacing to this new panel is a simple task through the industry standard CameraLink port. The high resolution receptor combined with a software-based command processor capable of 30 frames per second makes this an ideal imager for microfocus X-ray applications. Computer tomography (CT) applications also benefit from the high dynamic range and uniform image quality across a wide X-ray range. |
PaxScan 1313 data sheet (PDF) |
|
|
|
The PaxScan® 2020 has been specifically designed to meet or exceed the unique imaging requirements for next generation cardio-vascular diagnostic imaging equipment and mobile C-arms. The high sensitivity of the CsI scintillator combined with proprietary noise management techniques allows for excellent low-dose imaging performance that surpasses image intensifier tube (IIT) devices. Other features include an optimal 2 cm border between the active matrix and the edge of the receptor, further optimization of the pixel architecture, and an improved Command Processor with extended mode memory and faster clock speed. |
PaxScan 2020 data sheet (PDF) |
|
|
|
|
The PaxScan® 2520E+ is a ruggedized portable X-ray imaging component designed for high-speed radiographic DR imaging in the field. A user-supplied laptop running Varian ViVA™ application software. |
PaxScan 2520E+ data sheet (PDF) |
|
|
|
|
PaxScan® 2520V PaxScan® 2520V Configuration Contact Us for Additional PaxScan Product Data Note: Unless otherwise indicated, Varian imagers are not sold for use as medical devices. Certain system integrators may have obtained FDA clearance for their integrated devices. Obtaining such clearances is the responsibility of the system manufacturer or integrator. |
PaxScan 2520V data sheet (PDF) |
|
|
|
|
The PaxScan® 3030 is our dedicated field-of-view (FOV) real-time flat panel detector (FPD) for diagnostic systems specializing in lower G.I. studies. The main system components are the 30 x 30cm 194µm-pixel amorphous silicon FPD, real-time image processor (Command Processor), and universal dual-output power supply. Excellent low-dose performance is achieved by combining Varian's proprietary readout electronics with the high sensitivity of a custom Cesium Iodide scintillator. This FPD makes an ideal replacement for 12" I.I. Tubes, particularly for remote R&F table-based. |
|
|
|
|
The PaxScan® 4030CB is specifically designed to meet the needs of Cone Beam X-ray imaging applications featuring multiple sensitivity ranges and extended dynamic range modes. The main System components are the 40 x 30cm 194µm-pixel amorphous silicon FPD, real-time image processor (Command Processor), and universal dual-output power supply. Excellent low-dose performance is achieved by combining Varian's proprietary readout electronics with the high sensitivity of a customer Cesium Iodide scintillator. |
PaxScan 4030CB data sheet (PDF) |
|
|
|
PaxScan Radiographic Imagers PaxScan 4030E Configuration Contact Us for Additional PaxScan Product Data Note: Unless otherwise indicated, Varian imagers are not sold for use as medical devices. Certain system integrators may have obtained FDA clearance for their integrated devices. Obtaining such clearances is the responsibility of the system manufacturer or integrator. |
PaxScan 4030E data sheet (PDF) |
|
|
| PaxScan 4336R data sheet (PDF) | |
|
|
| PaxScan 4343R data sheet (PDF) | |