Varian produces and develops a wide variety of X-ray tubes for industry and science. Through development and acquisitions of Machlett Labs, Amperex and General Electric's industrial X-ray business, Varian has gained expertise and experience producing X-ray tubes used for X-ray Fluorescence (XRF) applications.
Varian pioneered the present day end-window, XRF tube, currently being used in all state-of-the-art X-ray Spectrometers. Varian's end-window XRF tube provides greater X-ray coupling to the sample which increases system sensitivity. Varian offers a complete line of XRF tubes used in wavelength and energy dispersive X-ray Spectrometers.
All Varian XRF tubes provide high X-ray intensity and spectral purity over the entire specified power range and throughout their life.
Cathode-Grounded, End Window X-ray Fluorescence (XRF) Tube
| Product Number |
|---|
| OEG-80J |
| OEG-75H |
| OEG-76H |
| EG-50 |
| EG-60 |
| VF-50 |
|
Maximum voltage | 75kV | |||||||||||||||||||||||
| Beryllium window | 0.003"(.76mm) | ||||||||||||||||||||||||
| Target Type | Single Target, Rh, Pt, Mo, Cr, W Maximum power 4kW | ||||||||||||||||||||||||
|
Power Rating
|
|||||||||||||||||||||||||
| Link to Datasheet | |||||||||||||||||||||||||
| Maximum voltage | 75kV |
|
|||||||||||||||||||||||||||
| Beryllium window | 0.005(.127mm) | ||||||||||||||||||||||||||||
| Target Type | Single Target, Rh, Pt, Mo, Cr, W, Cu | ||||||||||||||||||||||||||||
| Maximum Power | 3kW | ||||||||||||||||||||||||||||
|
Power Rating
|
|||||||||||||||||||||||||||||
| Link to Datasheet | |||||||||||||||||||||||||||||
|
Maximum voltage | 75kV | ||||
| Beryllium window | 0.005" (.127mm) | |||||
| Target Type | Single Target, Rh, Pt, Mo, Cr, W Maximum power 3kW | |||||
|
Power Rating
|
||||||
| Link to Datasheet | ||||||
|
Maximum voltage | 50kV | |||||||||||||||||||||||||||||||||||
| Beryllium window |
E=0.030(.762mm)
H=0.005(.127mm) |
||||||||||||||||||||||||||||||||||||
| Target Type | Single Target, Rh, Pt, Mo, Ti, W | ||||||||||||||||||||||||||||||||||||
| Maximum Power | 200 Watts | ||||||||||||||||||||||||||||||||||||
|
Power Rating
|
|||||||||||||||||||||||||||||||||||||
| Link to Datasheet | |||||||||||||||||||||||||||||||||||||
| Maximum voltage | 60kV |
|
|||||||||||||||||||||||||||||||
| Beryllium window |
E= .030 (.762mm)
J= .003 (.076mm) |
||||||||||||||||||||||||||||||||
| Target Type | Single Target Rh, Pd, Pt, Mo, W, Ti | ||||||||||||||||||||||||||||||||
|
Power Rating
|
|||||||||||||||||||||||||||||||||
| Link to Datasheet | |||||||||||||||||||||||||||||||||
|
Maximum voltage | 50kV | |||||||||||||||||||||||||
| Beryllium window | .003 (.076mm) | ||||||||||||||||||||||||||
| Target Type | Single Target Rh, Pd, Ti, Mo, W, Cu, S, Cr | ||||||||||||||||||||||||||
| Maximum Power | 50 Watts (Ti = 20 Watts) | ||||||||||||||||||||||||||
|
Power Rating
|
|||||||||||||||||||||||||||
| Link to Datasheet | |||||||||||||||||||||||||||