Varian manufactures a line of industrial X-ray tubes for applications in non-destructive testing (NDT), X-ray inspection, baggage screening, and thickness gauging. The company’s NDT product line consists of a broad range of glass and ceramic X-ray tubes providing a variety of target angles, focal spots, and power capabilities. For inspection applications that require different imaging parameters, Varian offers dual and single focus X-ray tubes with small focal spots for high-resolution imaging. In addition, Varian offers X-ray tubes with Beryllium (Be) windows for low inherent filtration.
NDI-160/20
D=1.0 mm
Maximum voltage
160kV
Target Angle
20°
Focal Spot Size
D=1.0 mm
Current
4mA@160kV
Inherent Filtration
1 mm BE
Download Datasheet
NDI-160/21
D=1.0 mm
Maximum voltage
160kV
Target Angle
20°
Focal Spot Size
D=3.0 mm
Current
10mA@160kV
Inherent Filtration
1 mm BE
Download Datasheet
NDI-160/22
D=1.0 mm
Maximum voltage
160kV
Target Angle
20°
Focal Spot Size
D=5.5 mm
Current
13mA@160kV
Inherent Filtration
1 mm BE
Download Datasheet
NDI-225/20
D=1.0 mm
Maximum voltage
225kV
Target Angle
20°
Focal Spot Size
D=1.0 mm
Current
2.5mA@225kV
Inherent Filtration
1 mm BE
Download Datasheet
NDI-225/21
D=1.0 mm
Maximum voltage
225kV
Target Angle
20°
Focal Spot Size
D=3.0 mm
Current
7mA@225kV
Inherent Filtration
1 mm BE
Download Datasheet
NDI-225/22
| Maximum voltage | 225kV |
|
| Target Angle | 20° | |
| Focal Spot Size |
D=1.0 mm
|
|
| Current | 5.5mA@225kV | |
| Inherent Filtration | 1 mm BE | |
| Download Datasheet | ||
NDI-320/26
D=3.0 mm
Maximum voltage
320kV
Target Angle
20°
Focal Spot Size
D=5.5 mm
Current
13MA@320kV
Inherent Filtration
4 mm BE
Download Datasheet
NDI-320/23
| Maximum voltage | 320kV |
|
| Target Angle | 20° | |
| Focal Spot Size |
D=1.9 mm
|
|
| Current | 5mA@320kV | |
| Inherent Filtration | 4 mm BE | |
| Download Datasheet | ||
NDI-321
D= 8.0 mm
Maximum voltage
320kV
Target Angle
20°
Focal Spot Size
Current
13mA@320kV
Inherent Filtration
4 mm BE
Download Datasheet
NDI-350/23
| Maximum voltage | 350kV |
|
| Target Angle | 20° | |
| Focal Spot Size |
D=1.9 mm
|
|
| Current | 5mA@350kV | |
| Inherent Filtration | 4 mm BE | |
| Download Datasheet | ||
NDI-350/26
D=3.0 mm
Maximum voltage
350kV
Target Angle
20°
Focal Spot Size
D=5.5 mm
Current
12mA@350kV
Inherent Filtration
4 mm BE
Download Datasheet
NDI-451
Maximum voltage
450kV
Target Angle
30°
Focal Spot Size
D=2.5 mm
D=5.5 mm
Current
10mA@450kV
Inherent Filtration
2.3 mm Fe + 1mm Cu
Download Datasheet
NDI-452
Maximum voltage
450kV
Target Angle
30°
Focal Spot Size
D=2.5 mm
D=5.5 mm
Current
10mA@450kV
Inherent Filtration
2.3 mm Fe + 1mm Cu
Download Datasheet