Articles

Members of Varian's Security and Inspection Products group are technical experts in the field of high-energy X-ray imaging for cargo screening and non-destructive testing. Here we archive a number of white papers and published articles by Varian authors, covering topics that range from the history of X-ray cargo screening to detection of weapons of mass destruction.

Cargo Security International Articles
  • Energy Driven by Dr. William Reed, Product Manger for New Products at Varian Medical Systems’ Security and Inspection Group (in Cargo Screening International, June/July 2007)
    (PDF 819k)
  • WMD Detection by Paul Bjorkholm (in Cargo Security International, June/July 2005)
    (PDF 912k)
  • The X Files: Part 1 by Paul Bjorkholm and James Johnson (in Cargo Screening International, June 2004)
    (PDF 568k)
  • The X Files: Part 2 by Paul Bjorkholm and James Johnson (in Cargo Screening International, August 2004)
    (PDF 489k)
  • The X Files: Part 3 by Paul Bjorkholm and James Johnson (in Cargo Screening International, October 2004)
    (PDF 612k)
CT Articles
  • Application of 450 kV Computed Tomography to Engine Blocks with Steel Liners by Charles R. Smith, Kevin M. Holt ( in ASNT, 2007)
    (PDF 400k)
  • Geometric Calibration of Third-Generation Computed Tomography Scanners From Scans of Unknown Objects Using Complementary Rays by Kevin M. Holt (in the ICIP 2007 technical program)
    (PDF 573)
  • Multi-Row Computed Tomography Detector by Charles R. Smith, Michael Z. Duncan, Timothy A. Fox (in ASNT, 2006)
    (PDF 302k)
  • Computed Tomography – an Inspection Tool for Production – Samples in an Aluminum Foundry by Charles R. Smith (in SAE Technical Papers, January 2006
    (PDF 372k)
  • The Potential for In-Line Casting Inspection with High Speed Multi-Row CT System by Charles R. Smith, Michael Z. Duncan, Timothy A. Fox ( in SAE Technical Papers, 2005)
    (PDF 351k)
  • CT Inspection of Castings with Improved Calibration by Charles R. Smith, Kyung S. Han (in SAE Technical Papers, January 2005)
    (PDF 929k)
  • Feldkamp-based cone-beam reconstruction for gantry-titled helical multislice CT by Ilmar Hein (in Medical Physics, December 2003)
    (PDF 819k)
Port Technology International Articles
  • X-ray cargo screening systems: the technology behind image quality by Dr. William A. Reed (in Port Technology International, Autumn 2007)
    (PDF 146k)
  • The economics of cargo screening by Dr. Paul Bjorkholm, Lester D. Boeh (in Port Technology International, Autumn 2006)
    (PDF 111k)
  • Dual Energy Detection of Weapons of Mass Destruction by Paul Bjorkholm (in Port Technology International, June 2005)
    (PDF 68k)
  • Optimising a Layered Port Security System by Paul Bjorkholm(in Port Technology International, January 2004)
    (PDF 114k)
  • Highly Integrated X-Ray System by Paul Bjorkholm (in Port Technology International, Autumn 2003)
    (PDF 189k)
  • Detection of Weapons of Mass Destruction by Paul Bjorkholm (in Port Technology International, June 2003)
    (PDF 139k)
  • Cargo Screening: Selection of Modality by Paul Bjorkholm (in Port Technology International, March 2003)
    (PDF 98k)
Varian Annual Report Articles
  • Accelerating Port Security (in Varian's 2004 annual report)
    (PDF 1,718k)
  • No Where to Hide: X-Rays and Homeland Security (in Varian's 2004 annual report)
    (PDF 1,718k)

 

© 1999-2008 Varian Medical Systems, Inc. All rights reserved.
Production of any of the material contained herein in any format or media without the express written permission of Varian Medical Systems is prohibited.

North America