Radiation Oncology Database Server Requirements (5U Rack Mounted)

Processor:
Dual Intel® Quad Core Xeon Processor E5430 2x6MB Cache, 2.66GHz, 1333MHz FSB
Bus Type:
PCI-E
Memory (DRAM):
4 GB Fully Buffered DIMM's at 667MHz Dual Ranked
Hard Drives:
4x146 GB Hot Swap drives with SAS interface (includes online spare). Drives should have < 10ms access time at 15000 RPM. Effective disk space is 292 GB.
Drive Controller:
Dual channel SAS 3.0Gb/s RAID controller with ≥ 256 MB cache. Configured for hardware RAID 5 fault tolerance and Read/Write cache enabled (software NOS controlled RAID 5 not recommended). CD and LTO tape should operate from channel 2 of controller or a separate controller.
Floppy Disk:
3.5" drive, 1.44 MB
Optical Drive:
Multisession 24X CD-RW and DVD-ROM combo Drive
Backup Tape:
LTO-4-120 800/1.6TB internal tape drive; BrightStor™ ARCserve® 11.5 or later.
Network Interface:
1 LOM 10/100/1000Mbps, compatible with the network operating system and cabling.
Redundancy:
PSU and Fans
Ports:
1 serial, minimum 2 USB
Network Operating System:
VARiS Vision: Microsoft® Windows® 2000 Server Standard, Service Pack 4 (Server 25 client access license or sufficient seat licenses)
ARIA: Microsoft® Windows® 2003 R2 Server (Standard or Enterprise) with Service Pack 2 (25 client access license or sufficient seat licenses)
File System:
NTFS
Microsoft® OS Architecture
32-bit (not 64-bit)
Microsoft® .NET Framework
1.1 and 2.0 (not 3.0)
42U Half Height Rack systems come with the following components (see notes below):
  • Cables for Keyboard and Video
  • NEMA standard power strip
  • 1U 8-port keyboard/monitor KVM switch box
  • 1U keyboard/trackball and monitor console
  • 2U 3000VA Uninterruptible Power Supply (UPS)
  • 24-port patch panel (CAT5E)

Notes:

  1. Hardware used should be approved based on the current Microsoft® Windows® Catalog Listing.
  2. In addition to this Database Server, the following Image Fileserver is required for use with all image-based products and would be installed in the same rack.
  3. 1 Gbps network recommended for maximum speed and performance.
  4. In addition to this database server, the following T-Box server is required and would be installed in the same rack.
  5. Specifications subject to change without notice as newer computer models become available.

 

Contact Varian Oncology

Varian Oncology Headquarters
Tel: 1.650.424.5700
Fax: 1.650.493.5637
E-Mail: ca@varian.com

Events

  • 9/10/2008 - 09/13/2008
    DGMP Meeting
  • 09/12/2008 - 09/16/2008
    33rd ESMO Congress
  • 09/13/2008
    5th European Systems Users Meeting
  • 09/14/2008 - 09/18/2008
    26th ESTRO Meeting

© 1999-2008 Varian Medical Systems, Inc. All rights reserved.
Production of any of the material contained herein in any format or media without the express written permission of Varian Medical Systems is prohibited.

North America EMEA - Europe, Middle East, India & Africa