Oncology | Radiation Oncology
ARIA | Hardware Specifications
Information Exchange Manager (IEM) Server Requirements (2U Rack Mounted)
- Processor:
- Dual Intel® Quad Core Xeon E5430 Processor2x6MB Cache, 2.66GHz, 1333MHz FSB (or better)
- Memory:
- 4 GB 667MHz Dual Ranked Fully Buffered DIMMs
- Hard Drives:
- 2x73 GB (OS/APP) Hot Swap drives with Serial Attached SCSI interface at 15,000 RPM (for system with no Medical Oncology Faxing or Scanning Interface) or
2x300 GB (OS/APP) Hot Swap drives with Serial Attached SCSI interface at 10000 RPM (for system with Medical Oncology Faxing or Scanning Interface)
- Drive Controller:
- Single channel SAS RAID controller. Configured for hardware RAID 1 fault tolerance.
- CD-ROM/DVD:
- CD Reader or DVD reader.
- Network Adapter:
- 1 Ethernet NIC 100/1000 Mbps.
- Redundancy:
- PSU and Fans
- Ports:
- minimum 2 USB
- Network Operating System:
- Microsoft® Windows® 2003 Server Standard Edition (English version only), Service Pack 2
Notes:
- Hardware used must be approved based on the current Microsoft® specifications.
- 1 Gbps network recommended for maximum speed and performance.
- The OS on the clinical production servers MUST match the OS on the HARRP server.
- If the customer is providing a filtered data feed, one IEM Server can normally support up to about 150 concurrent users. If there is a substantial amount of filtering required in the IEM Server, fewer concurrent users may be supported on one interface engine. Another parameter to evaluate is the number of messages per day. If there is a need to parse in excess of about 50,000 messages a day, additional IEM Servers may be needed.