(HARRP) Server Requirements (5U Rack Mounted)
(Prerequisite: Database Server and/or Image Fileserver)
| System Size | Small | Medium | Large |
|---|---|---|---|
| Processor: | Dual Intel® Quad Core Xeon E5440 Processor 2x6MB Cache, 2.83GHz, 1333MHz FSB | Dual Intel® Quad Core Xeon E5440 Processor 2x6MB Cache, 2.83GHz, 1333MHz FSB | Dual Intel® Quad Core Xeon E5440 Processor 2x6MB Cache, 2.83GHz, 1333MHz FSB |
| Bus Type: | PC-E | PC-E | PC-E |
| Memory (RAM): | 2 GB Fully Buffered DIMM'S at 667MHz Dual Ranked | 8 GB Fully Buffered DIMM'S at 667MHz Single Ranked | 8 GB Fully Buffered DIMM'S at 667MHz Single Ranked |
| Hard Disk: | 3x146 GB Hot Swap drives with SAS interface (includes online spare). Drives should have < 10ms access time at 15 000 RPM. Effective disk space is 146 GB. | 3x146 GB Hot Swap drives with SAS interface (includes online spare). Drives should have < 10ms access time at 15 000 RPM. Effective disk space is 146 GB. | 3x146 GB Hot Swap drives with SAS interface (includes online spare). Drives should have < 10ms access time at 15 000 RPM. Effective disk space is 146 GB. |
| Drive Controller: | Dual channel SAS 3.0Gb/s RAID controller with ≥ 256 MB cache. Configured for hardware RAID 1 fault tolerance with hot spare (software NOS controlled RAID 1 not recommended) and an one additional SAS RAID controller with external port configured for hardware RAID 5 fault tolerance (software NOS controlled RAID 5 not recommended). CD should operate from separate controller or channel 2 of controller. | Dual channel SAS 3.0Gb/s RAID controller with ≥ 256 MB cache. Configured for hardware RAID 1 fault tolerance with hot spare (software NOS controlled RAID 1 not recommended) and an one additional SAS RAID controller with external port configured for hardware RAID 5 fault tolerance (software NOS controlled RAID 5 not recommended). CD should operate from separate controller or channel 2 of controller. | Dual channel SAS 3.0Gb/s RAID controller with ≥ 256 MB cache. Configured for hardware RAID 1 fault tolerance with hot spare (software NOS controlled RAID 1 not recommended) and an one additional SAS RAID controller with external port configured for hardware RAID 5 fault tolerance (software NOS controlled RAID 5 not recommended). CD should operate from separate controller or channel 2 of controller. |
| Floppy Disk: | N/A | N/A | N/A |
| Optical Drive: | Multisession 24X CD-RW and DVD-ROM combo Drive | Multisession 24X CD-RW and DVD-ROM combo Drive | Multisession 24X CD-RW and DVD-ROM combo Drive |
| Network Interface: | 1 LOM 10/100/1000 Mbps, compatible with the network operating system and cabling. | 1 LOM 10/100/1000 Mbps, compatible with the network operating system and cabling. | 1 LOM 10/100/1000 Mbps, compatible with the network operating system and cabling. |
| Redundancy: | PSU | PSU | PSU |
| Ports: | 1 serial, minimum 2 USB | 1 serial, minimum 2 USB | 1 serial, minimum 2 USB |
| Network Operating System: | VARiS Vision: Microsoft® Windows® 2000 Server Standard, Service Pack 4 (Server 5 client access license or sufficient seat licenses) ARIA: Microsoft® Windows® Server 2003 R2 (Standard or Enterprise) with Service Pack 2 (5 client access license or sufficient seat licenses) |
VARiS Vision: Microsoft® Windows® 2000 Server Standard, Service Pack 4 (Server 5 client access license or sufficient seat licenses) ARIA: Microsoft® Windows® Server 2003 R2 (Standard or Enterprise) with Service Pack 2 (5 client access license or sufficient seat licenses) |
VARiS Vision: Microsoft® Windows® 2000 Server Standard, Service Pack 4 (Server 5 client access license or sufficient seat licenses) ARIA: Microsoft® Windows® Server 2003 R2 (Standard or Enterprise) with Service Pack 2 (5 client access license or sufficient seat licenses) |
| File System | NTFS | NTFS | NTFS |
| Microsoft® OS Architecture | 32-bit (not 64-bit) | 32-bit (not 64-bit) | 32-bit (not 64-bit) |
| Microsoft® .NET Framework | 1.1 and 2.0 (not 3.0) | 1.1 and 2.0 (not 3.0) | 1.1 and 2.0 (not 3.0) |
| System Size | Small | Medium | Large |
|---|---|---|---|
| Hard Disk: | 5x146 GB Hot Swap drives with Ultra-320 SCSI interface (includes online spare). Drives should have < 10ms access time at 15000 RPM. Effective disk space is 438 GB. | 7x300 GB Hot Swap drives with Ultra-320 SCSI interface (includes online spare). Drives should have < 10ms access time at 15000 RPM. Effective disk space is 1.5 TB. | 9x300 GB Hot Swap drives with Ultra-320 SCSI interface (includes online spare). Drives should have < 10ms access time at 15000 RPM. Effective disk space is 2.1 TB. |
| Redundancy: | PSU | PSU | PSU |
| Additional Software: | DoubleTake™ for Windows® Server Standard. One license required per server (3 licenses at minimum are required) | DoubleTake™ for Windows® Server Standard. One license required per server (3 licenses at minimum are required) | DoubleTake™ for Windows® Server Standard. One license required per server (3 licenses at minimum are required) |