Citrix Server Recommendations (Tower or Rack - 1U)

Processor:
Dual Intel® Xeon® [5130 Dual|5430 Quad] Core Processors at 2.66 GHz, 1333MHz FSB with [2X 4MB|2X 6MB] cache. (or better)
Memory:
4 GB RAM
Hard Drives:
2x36 GB (OS/APP) Hot Swap drives with Serial Attached SCSI interface at 15,000 RPM
Drive Controller:
Single channel SAS RAID controller. Configured for hardware RAID 1 fault tolerance.
CD-ROM/DVD:
CD Reader or DVD reader
Network Adapter:
1 Dual Ethernet NIC 100/1000 Mbps.
Redundancy:
PSU and Fans
Ports:
Minimum 2 USB
Network Operating System:
Microsoft® Windows® 2003 Server (R2) Standard Edition (English version only), Service Pack 1
Service Pack:
SP1
Other Software:
ARIA for Medical Oncology Citrix Presentation Server 4.0
ARIA for Radiation Oncology Citrix Presentation Server 4.0 Enterprise Edition

Notes:

  1. Recommended configuration above is for a Single Citrix Server or the First Server in a Citrix Farm.
  2. Load Balancing and High Availability (N+1) Citrix Server shall use the same recommended hardware; however, RAID controllers, hot spare drives, and redundant power supplies are not required.
  3. Hardware used with ARIA must be approved based on the current Microsoft® specifications.
  4. 1 Gbps network recommended for maximum speed and performance.
  5. Hard Drive Partitions (2) with OS → C:=12GB; APP → D:=24GB
  6. ARIA for Medical Oncology will normally support approximately 50 concurrent users on one (1) Citrix Server.
  7. ARIA for Radiation Oncology will normally support the following concurrent users per one (1) Citrix Server:
    ARIA Clients
    (Patient Manager, Time Planner, ...)
    30Textual data
    Radiation Oncology
    (RTChart, ...)
    20 – 30Textual and 2-D Image data
    Eclipse10Textual and 2-D/3-D Image data
  8. Additional Citrix Server is recommended if high availability load balancing is desired for each configured set of users (N+1 configuration).
  9. Additional Citrix Servers should be planned and accounted based on concurrent user count.
  10. Virtualization of Citrix Servers is currently not supported.

  11. A second Citrix Server is recommended if high availability load balancing is desired for each set of 50 users (N+1 configuration).
    Additional Citrix Servers should be planned for based on concurrent user count.

 