Oncology | Radiation Oncology
ARIA | Hardware Specifications
Citrix Server Recommendations (Tower or Rack - 1U)
- Processor:
- Dual Intel® Xeon® [5130 Dual|5430 Quad] Core Processors at 2.66 GHz, 1333MHz FSB with [2X 4MB|2X 6MB] cache. (or better)
- Memory:
- 4 GB RAM
- Hard Drives:
- 2x36 GB (OS/APP) Hot Swap drives with Serial Attached SCSI interface at 15,000 RPM
- Drive Controller:
- Single channel SAS RAID controller. Configured for hardware RAID 1 fault tolerance.
- CD-ROM/DVD:
- CD Reader or DVD reader
- Network Adapter:
- 1 Dual Ethernet NIC 100/1000 Mbps.
- Redundancy:
- PSU and Fans
- Ports:
- Minimum 2 USB
- Network Operating System:
- Microsoft® Windows® 2003 Server (R2) Standard Edition (English version only), Service Pack 1
- Service Pack:
- SP1
- Other Software:
- ARIA for Medical Oncology Citrix Presentation Server 4.0
ARIA for Radiation Oncology Citrix Presentation Server 4.0 Enterprise Edition
Notes:
- Recommended configuration above is for a Single Citrix Server or the First Server in a Citrix Farm.
- Load Balancing and High Availability (N+1) Citrix Server shall use the same recommended hardware; however, RAID controllers, hot spare drives, and redundant power supplies are not required.
- Hardware used with ARIA must be approved based on the current Microsoft® specifications.
- 1 Gbps network recommended for maximum speed and performance.
- Hard Drive Partitions (2) with OS → C:=12GB; APP → D:=24GB
- ARIA for Medical Oncology will normally support approximately 50 concurrent users on one (1) Citrix Server.
- ARIA for Radiation Oncology will normally support the following concurrent users per one (1) Citrix Server:
ARIA Clients
(Patient Manager, Time Planner, ...) | 30 | Textual data |
Radiation Oncology
(RTChart, ...) | 20 – 30 | Textual and 2-D Image data |
| Eclipse | 10 | Textual and 2-D/3-D Image data |
- Additional Citrix Server is recommended if high availability load balancing is desired for each configured set of users (N+1 configuration).
- Additional Citrix Servers should be planned and accounted based on concurrent user count.
- Virtualization of Citrix Servers is currently not supported.
A second Citrix Server is recommended if high availability load balancing is desired for each set of 50 users (N+1 configuration).
Additional Citrix Servers should be planned for based on concurrent user count.