Radiation Oncology Database Server

Specs Database Server Rack Database Server Rack without Backup
Model: Dell T610 Rack Dell T610 Rack
Processor: 2x Intel Xeon 5520 (2.26GHz, 5.86GT/s, 8MB) 2x Intel Xeon 5520 (2.26GHz, 5.86GT/s, 8MB)
RAM: 12GB (6x2GB) 1066MHz DDR3 ECC-RDIMM 12GB (6x2GB) 1066MHz DDR3 ECC-RDIMM
Harddisk: 8x 146GB SAS 15'000 RPM 8x 146GB SAS 15'000 RPM
Size to be backuped: 730 GB 730 GB
Backup: LTO-4-120, 800/1600 GB Half Height Internal Drive N/A
RAID: C: + D: = RAID5 (584GB)
E: = RAID1 (146GB)
1 Global Hot Spare for C:, D: and E: Drive
C: + D: = RAID5 (584GB)
E: = RAID1 (146GB)
1 Global Hot Spare for C:, D: and E: Drive
Network: Broadcom Netextreme II NIC-Card Broadcom Netextreme II NIC-Card
Power: Redudant Power Supply 870 Watt Redudant Power Supply 870 Watt
Floppy: No Floppy Drive No Floppy Drive
Optical Drive: 16x DVD+/- RW 16x DVD+/- RW
Keyboard / Mouse: Not included Not included
Operating System: Microsoft Windows Server 2008 Standard 64bit (until A10 with Windows Server 2003 Standard 32bit) Microsoft Windows Server 2008 Standard 64bit (until A10 with Windows Server 2003 Standard 32bit)
Notes: Incl. sliding ready Rails with Cable Management Arm. To be used only for sites with centralized backup solution. Incl. sliding ready Rails with Cable Management Arm.
42U Half Height Rack systems come with the following components (see notes below):
  • Cables for Keyboard and Video
  • NEMA standard power strip
  • 1U 8-port keyboard/monitor KVM switch box
  • 1U keyboard/trackball and monitor console
  • 2U 3000VA Uninterruptible Power Supply (UPS)
  • 24-port patch panel (CAT5E)

Notes:

  1. Virtualization of the Database Server is currently not available nor supported.
  2. Software RAID is neither recommended nor supported with this Database Server.
  3. Database Server does not include a tape backup device package.
    a. An optional external tape backup device package, however, is available for sites without an Image Fileserver, and should operate from a separate drive controller.
  4. Hardware used should be approved based on the current Microsoft® Windows® Catalog Listing.
  5. Other compatible Windows® Operating Systems include: Windows® Server 2003 (Standard or Enterprise) with SP2.
  6. In addition to this Database Server, the following Image File Server is required for use with all image-based products and would be installed in the same rack.
  7. The Operating System (build and version) on the Database Server shall match the Operating System (build and version) on the HARRP server.
  8. 1 Gbps network recommended for maximum speed and performance.
  9. CPU identified above is for Intel®'s Nehalem (microarchitecture). Each CPU has three separate memory controller hubs (MCHs) within the CPU package, and requires each memory channel to be populated per CPU for optimal use.
  10. Specifications subject to change without notice as newer computer models become available.

 

Contact Varian Oncology

Varian Oncology Headquarters
Tel: 1.650.424.5700
Contact Us

Events

Print Normal Bigger Large

© 1999-2012 Varian Medical Systems, Inc. All rights reserved.
Production of any of the material contained herein in any format or media without the express written permission of Varian Medical Systems is prohibited.