| Specs |
Database Server Rack |
Database Server Rack without Backup |
| Model: |
Dell T610 Rack |
Dell T610 Rack |
| Processor: |
2x Intel Xeon 5620 (2.40GHz, 5.86GT/s, 12MB) |
2x Intel Xeon 5620 (2.40GHz, 5.86GT/s, 12MB) |
| RAM: |
12GB (6x2GB) 1333MHz DDR3 ECC-RDIMM |
12GB (6x2GB) 1333MHz DDR3 ECC-RDIMM |
| Harddisk: |
8x 146GB SAS 15'000 RPM |
8x 146GB SAS 15'000 RPM |
| Size to be backuped: |
730 GB |
730 GB |
| Backup: |
LTO-4, 800GB Half Height Internal Drive incl H200 Controller |
N/A |
| RAID: |
C: + D: = RAID5 (584GB) E: = RAID1 (146GB) 1 Global Hot Spare for C:, D: and E: Drive |
C: + D: = RAID5 (584GB) E: = RAID1 (146GB) 1 Global Hot Spare for C:, D: and E: Drive |
| Network: |
Broadcom Netextreme II NIC-Card |
Broadcom Netextreme II NIC-Card |
| Power: |
Redudant Power Supply 870 Watt |
Redudant Power Supply 870 Watt |
| Floppy: |
No Floppy Drive |
No Floppy Drive |
| Optical Drive: |
16x DVD+/- RW |
16x DVD+/- RW |
| Keyboard / Mouse: |
Not included |
Not included |
| Operating System: |
Microsoft Windows Server 2008 Standard 64bit |
Microsoft Windows Server 2008 Standard 64bit |
| Notes: |
Incl. sliding ready Rails with Cable Management Arm. |
To be used only for sites with centralized backup solution. Incl. sliding ready Rails with Cable Management Arm. |
Notes:
- Software RAID is neither recommended nor supported with the ARIA Radiation Oncology Server.
- Hardware used should be approved based on the current Microsoft® Windows® Catalog Listing.
- Windows® Server 2008 R2 is currently not compatible with ARIA Version 10.0
- Other compatible Windows® operating systems include: Windows Server 2003 and Windows Server 2003 R2, Standard or Enterprise, SP2, 32-bit only.
- The Operating System (build and version) of the ARIA Radiation Oncology Server must match the operating system (build and version) of the HARRP target server.
- 1 Gbps network recommended for maximum speed and performance.
- CPU identified above is for Intel®'s Nehalem or Westmere (microarchitecture). Each CPU has up to three or four separate memory controller hubs (MCHs) within the CPU package, and requires each memory channel to be populated per CPU for optimal use.
- Specifications subject to change without notice as newer computer models become available.
42U Half Height Rack systems come with the following components (see notes below):
- Cables for Keyboard and Video
- NEMA standard power strip
- 1U 8-port keyboard/monitor KVM switch box
- 1U keyboard/trackball and monitor console
- 2U 3000VA Uninterruptible Power Supply (UPS)
- 24-port patch panel (CAT5E)