Information Exchange Manager (IEM) Server Requirements - Rack Mounted

Platform: DELL® R610 - (1U)
Processor: (Dual) Intel® Xeon® X5650, 2.66Ghz, 12M Cache,Turbo, HT, 1333MHz
Bus Type: PCI-E
Memory (RAM): 24GB Memory (6x4GB), 1333MHz Dual Ranked RDIMMs for 2 Processors, Optimized
Hard Drives (Local Storage): 4x146GB 15K RPM Serial-Attach SCSI 6Gbps 2.5” Hot Plug Hard Drive.
Drive Controller: Internal PERC H700 Integrated RAID[1] Controller with 512MB of battery-backed cache with (50/50) read/write cache enabled
  • Configure channel one: 4x146GB (RAID 5 + 1HS)
  • DVD operates from SATA CONTROLLER ON BOARD
  • Optical Drive: Internal Slim optical DVD ROM
    Network Interface: Dual Two-Port Embedded Broadcom® NetXtreme II™ 5709 Gigabit Ethernet NIC
    Redundancy: PSU and Fans
    Ports: 1 serial, minimum 2 USB
    Operating System[3], [4], [5]: Windows® Server 2008 R1 (Standard) with Service Pack 2 (5 client access license or sufficient seat licenses)
    File System:
    NT File System (NTFS)
    Server
    • Volume C: 80GB
    • Volume D: ~212GB
    Windows® OS Architecture: 64-bit

    Notes:

    1. Software RAID is neither recommended nor supported with the IEM Server.
    2. Hardware used should be approved based on the current Microsoft® Windows® Catalog Listing.
    3. Windows® Server 2008 R2 is currently not compatible with IEM.
    4. Other compatible Windows® operating systems include: Windows Server 2003 and Windows Server 2003 R2, Standard or Enterprise, SP2, 32-bit only.
    5. If the faxing interface is installed, this interface is only compatible within a 32-bit operating system not a 64-bit operating system.
    6. The Operating System (build and version) of the IEM Server must match the operating system (build and version) of the HARRP target server.
    7. 1 Gbps network recommended for maximum speed and performance.
    8. CPU identified above is for Intel®'s Nehalem or Westmere (microarchitecture). Each CPU has up to three or four separate memory controller hubs (MCHs) within the CPU package, and requires each memory channel to be populated per CPU for optimal use.
    9. Specifications subject to change without notice as newer computer models become available.

     