HARRP Comprehensive Cancer Solution (CCS) Single Server -- Rack Mounted

Small Medium Large
Platform: DELL® R510 - (2U) DELL® R810 - (2U) DELL® R810 - (2U)
Processor: (Dual) Intel® Xeon® E5620 2.4Ghz, 12M Cache,Turbo, HT, 1066MHz (Dual) Intel® Xeon® E7540 2.00GHz, 18M cache, 6.40 GT/s QPI, Turbo, HT, 6C (Quad) Intel® Xeon® E7540 2.00GHz, 18M cache, 6.40 GT/s QPI, Turbo, HT, 6C
Bus Type: PCI-E PCI-E PCI-E
Memory (RAM): 24GB Memory (6x4GB), 1333MHz Dual Ranked RDIMMs for 2 Processors, Optimized 32GB Memory (16x2GB), 1066MHz, Dual Ranked RDIMMs for 2 or 4 Processors 64GB Memory (16x4GB), 1066MHz, Quad Ranked RDIMMs for 2 or 4 Processors
Drive Controllers: Internal PERC H700 Integrated RAID[1] Controller with 512MB of battery-backed cache with (50/50) read/write cache enabled
  • Configure channel one: 2x146GB (RAID 1); 4x146GB (RAID 5)

  • Configure channel two: 6x600GB (RAID 5 + 1 Global HS)

  • Internal PERC H700 Integrated RAID[1] Controller with 512MB of battery-backed cache with (50/50) read/write cache enabled
  • Configure channel one: 3x146GB (RAID 1 + 1HS)

  • DVD operates from SATA CONTROLLER ON BOARD

  • External PERC H800 Integrated RAID[1] Controller with 512MB of battery-backed cache with (50/50) read/write cache enabled
  • Configure channel one: 3x146GB (RAID 1 + 1HS), 7x600GB (RAID 5 + 1HS)
  • Configure channel two: 9x146GB (RAID 5 + 1HS)
  • Internal PERC H700 Integrated RAID[1] Controller with 512MB of battery-backed cache with (50/50) read/write cache enabled
  • Configure channel one: 3x146GB (RAID 1 + 1HS)

  • DVD operates from SATA CONTROLLER ON BOARD

  • External PERC H800 Integrated RAID[1] Controller with 512MB of battery-backed cache with (50/50) read/write cache enabled
  • Configure channel one: 3x146GB (RAID 1 + 1HS), 9x600GB (RAID 5 + 1HS)
  • Configure channel two: 12x146GB (RAID 5 + 1HS)
  • Hard Drives:
    Local Storage
  • 6x146GB 15K RPM Serial-Attach SCSI 3Gbps 3.5” Hot Plug Hard Drive

  • 6x600GB 15K RPM Serial-Attach SCSI 6Gbps 3.5” Hot Plug Hard Drive
  • 3x146GB 15K RPM Serial-Attach SCSI 6Gbps 2.5” Hot Plug Hard Drive
  • 3x146GB 15K RPM Serial-Attach SCSI 6Gbps 2.5" Hot Plug Hard Drive
  • Direct Attached Storage Array (DAS):
    External
    None PowerVault MD1220 with 24 HDD capacity - (2U) PowerVault MD1220 with 24 HDD capacity - (2U)
    Hard Drives (DAS) None
  • 12x146GB 15K RPM Serial-Attach SCSI 6Gbps 2.5" Hot Plug Hard Drive
  • 7x600GB 10K RPM Serial-Attach SCSI 6Gbps 2.5" Hot Plug Hard Drive
  • 15x146GB 15K RPM Serial-Attach SCSI 6Gbps 2.5" Hot Plug Hard Drive
  • 9x600GB 10K RPM Serial-Attach SCSI 6Gbps 2.5" Hot Plug Hard Drive
  • Optical Drive: External USB Slim optical DVD ROM Internal Slim optical DVD ROM Internal Slim optical DVD ROM
    Network Interface: Dual Two-Port Embedded Broadcom® NetXtreme II™ 5709 Gigabit Ethernet NIC Dual Two-Port Embedded Broadcom® NetXtreme II™ 5709 Gigabit Ethernet NIC Dual Two-Port Embedded Broadcom® NetXtreme II™ 5709 Gigabit Ethernet NIC
    Redundancy: PSU and Fans PSU and Fans PSU and Fans
    Ports: 1 serial, minimum 2 USB 1 serial, minimum 2 USB 1 serial, minimum 2 USB
    Operating System[3]: ARIA (Version 10.0): Windows® Server 2008 R1 (Standard) with Service Pack 2 (25 client access license or sufficient seat licenses) ARIA (Version 10.0): Windows® Server 2008 R1 (Enterprise) with Service Pack 2 (25 client access license or sufficient seat licenses) ARIA (Version 10.0): Windows® Server 2008 R1 (Enterprise) with Service Pack 2 (25 client access license or sufficient seat licenses)
    File System:
    NT File System (NTFS)
    Server
    • Volume C, (OS & APP): 146GB (RAID 1) @ 15K RPM;
    • Volume D, (Database & Database Logs): ~438GB (RAID 5) @ 15K RPM;
    • Volume E, (Image Directory & Database Dumps): ~2.3TB (RAID 5) @ 15K RPM.
    Server
    • Volume C, (OS & APP): 146GB (RAID 1) @ 15K RPM;
    Direct Attached Storage
    • Volume D, (Database): ~1.0TB (RAID 5) @ 15K RPM;
    • Volume E, (Database Logs): 146GB (RAID 1) @ 15K RPM;
    • Volume F, (Image Directory & Database Dumps): ~3.0TB (RAID 5) @ 10K RPM.
    Server
    • Volume C, (OS & APP): 146GB (RAID 1) @ 15K RPM;
    Direct Attached Storage
    • Volume D, (Database): ~1.4TB (RAID 5) @ 15K RPM;
    • Volume E, (Database Logs): 146GB (RAID 1) @ 15K RPM;
    • Volume F, (Image Directory & Database Dumps): ~4.2TB (RAID 5) @ 10K RPM.
    Windows® OS Architecture: 64-bit 64-bit 64-bit
    Microsoft® .NET Framework: ARIA (10.0): 1.1, 2.0, 3.0 and 3.5 ARIA (10.0): 1.1, 2.0, 3.0 and 3.5 ARIA (10.0): 1.1, 2.0, 3.0 and 3.5
    Other Software: Double-Take™ for Windows® Server Standard or Advanced. One license required per server. Double-Take™ for Windows® Server Standard or Advanced. One license required per server. Double-Take™ for Windows® Server Standard or Advanced. One license required per server.

    Notes:

    1. Software RAID is neither recommended nor supported with this Database Server.
    2. Hardware used should be approved based on the current Microsoft® Windows® Catalog Listing.
    3. Windows® Server 2008 R2 is currently not compatible with ARIA Version 10.0
    4. The Operating System (build and version) of the ARIA CCS Single Server must match the Operating System (build and version) of the HARRP target server.
    5. Primary (source) and HARRP (target) servers should not be placed in the same rack or location for optimum reliability.
    6. 1 Gbps network recommended for maximum speed and performance.
    7. CPU identified above is for Intel®'s Nehalem or Westmere (microarchitecture). Each CPU has up to four separate memory controller hubs (MCHs) within the CPU package, and requires each memory channel to be populated per CPU for optimal use.
    8. Double-Take® Standard licenses only work with Windows® Standard Operating Systems.
    9. Double-Take® Advanced licenses only work with Windows® Advanced or Enterprise Operating Systems.
    10. Specifications subject to change without notice as newer computer models become available.
    11. Optional full height rack available at extra cost.

    24U Half Height Rack systems come with the following components:

    • 24U Short Rack
    • Cables for Keyboard and Video
    • NEMA standard power strip
    • 1U 8-port keyboard/monitor KVM switch box
    • 1U keyboard/trackball and monitor console
    • 2U 3000VA Uninterruptable Power Supply (UPS)
    • 24-port patch panel (CAT5E)

     

    Print Normal Bigger Large

    © 1999-2012 Varian Medical Systems, Inc. All rights reserved.
    Production of any of the material contained herein in any format or media without the express written permission of Varian Medical Systems is prohibited.

    產品索引A至Z