Processor:
Dual X5550 Xeon Processor, 2.66GHz 8M Cache, Turbo, HT
Memory:
6GB Memory (6x1GB), 1333MHz Single Ranked UDIMMs for 2 Processors, Optimized
Hard Drives:
3x146 GB, 15K RPM, Serial-Attach SCSI 3.5" Hot Plug Hard Drive (includes online spare)
Drive Controller:
Internal PERC 6/i Dual Channel SAS 3.0 GB/s RAID controller with 256 MB of battery-backed cache.
Configure 2x146GB OS/APP (RAID 1) with one online spare.
DVD operates from SATA CONTROLLER ON BOARD
Floppy Disk:
None
Optical Drive:
Internal Slim optical DVD + RW
Network Adapter:
Dual Two-Port Embedded Broadcom® NetXtreme II™ 5709 Gigabit Ethernet NIC
Redundancy:
PSU and Fans
Ports:
Minimum 2 USB
Operating System:
Microsoft® Windows® Server 2003 R2, Standard Edition (English version only), (5 client access licenses or sufficient seat licenses)
File System:
NT File System (NTFS)
Partition C: → 30GB
Partition D: → 116GB
Microsoft® OS Architecture:
32-bit (not 64-bit)
Microsoft® .NET Framework:
ARIA(8.0 ≥ 8.5): 1.1 and 2.0 (not 3.0 or 3.5)
ARIA(8.6, 8.8): 1.1, 2.0, 3.0 and 3.5
Other Software:
  • Microsoft® Terminal Client Access Licenses
  • Citrix Presentation Server 4.0 → ARIA for Medical Oncology
  • Citrix XenApp 4.5 → ARIA for Medical Oncology
  • Citrix Presentation Server 4.0 Enterprise Edition (English only) → ARIA for Radiation Oncology and Eclipse (v8.1 ≥ v8.8) -
  • Citrix XenApp 4.5 Enterprise Edition (English only) → ARIA for Radiation Oncology and Eclipse (v8.1 ≥ v8.8)

Notes:

  1. CPU identified above is for Intel®'s Nehalem (microarchitecture). Each CPU has three separate memory controller hubs (MCHs) within the CPU package, and requires each memory channel to be populated per CPU for optimal use.
  2. Virtualization of Citrix Servers is currently unavailable.
  3. Review the Citrix Road Map on qualifying Citrix Presentation Server and XenApp with ARIA for Radiation Oncology and Eclipse.
  4. Recommended configuration above is for a Single Citrix Server or the First Server in a Citrix Farm.
  5. Load Balancing and High Availability (N+1) Citrix Server shall use the same recommended hardware; however, RAID controllers, hot spare drives, and redundant power supplies are not required.
  6. 1 Gbps network recommended for maximum speed and performance.
  7. Specifications subject to change without notice as newer computer models become available.
  8. Hardware used with ARIA for Radiation Oncology and Eclipse must be approved based on the current Microsoft® specifications.
  9. Additional Citrix Servers should be planned and accounted for based on concurrent user count.
  10. ARIA for Medical Oncology will normally support approximately 50 concurrent users on one (1) Citrix Server.
  11. ARIA for Radiation Oncology will normally support these concurrent users on one (1) Citrix Server per Client Type row but not combined in the table below:

  12. Client Type Users Data Type
    ARIA Practice Management
    (Patient Manager, Time Planner, ...)
    30   Textual data
    ARIA Radiation Oncology
    (RTChart, ...)
    10   Textual and 2-D Image data
    Offline Review 5   Textual and 2-D/3-D Image data
    Eclipse 5   Textual and 2-D/3-D Image data
    PurView 4 Textual and 2-D/3-D Image data

  13. ARIA for Radiation Oncology and Eclipse are currently unavailable with national language support for use over any Citrix version.
  14. Specifications subject to change without notice as newer computer models become available.

 

Contact Varian Oncology

Varian Oncology Headquarters
Tel: 1.650.424.5700
Contact Us

Events

Print Normal Bigger Large

© 1999-2012 Varian Medical Systems, Inc. All rights reserved.
Production of any of the material contained herein in any format or media without the express written permission of Varian Medical Systems is prohibited.

产品索引 A 至 Z