Duet Server Requirements - Rack Mounted

System Size Small and Medium Large
Platform: DELL® R510 - (2U) DELL® R510 - (2U)
Processor: Single Intel® Xeon® E5530, 2.4Ghz, 8M Cache, 5.86 GT/s QPI, Turbo, HT, 1066MHz Single Intel® Xeon® X5650, 2.66Ghz, 12M Cache,Turbo, HT, 1333MHz
Bus Type: PCI-E PCI-E
Memory (RAM): 8GB Memory (4x2GB), 1333MHz Dual Ranked RDIMMs for 1 Processors, Optimized 12GB Memory (3x4GB), 1333MHz Dual Ranked RDIMMs for 1 Processor, Optimized
Hard Drives: (Local Storage) 6x450GB 15K RPM Serial-Attach SCSI 6Gpbs 3.5” Hot Plug Hard Drive. 6x600GB 15K RPM Serial-Attach SCSI 6Gpbs 3.5” Hot Plug Hard Drive.
Drive Controller: Internal PERC H700 Integrated RAID[1] Controller with 512MB of battery-backed cache with (50/50) read/write cache enabled
  • Configure channel one: 6x450GB (RAID 5 + 1HS)
  • DVD operate from SATA CONTROLLER ON BOARD
  • Internal PERC H700 Integrated RAID[1] Controller with 512MB of battery-backed cache with (50/50) read/write cache enabled
  • Configure channel one: 6x600GB (RAID 5 + 1HS)
  • DVD operates from SATA CONTROLLER ON BOARD
  • Optical Drive: Internal Slim optical DVD ROM Internal Slim optical DVD ROM
    Backup Tape: None[2] None[2]
    Network Interface: Dual Two-Port Embedded Broadcom® NetXtreme II™ 5709 Gigabit Ethernet NIC Dual Two-Port Embedded Broadcom® NetXtreme II™ 5709 Gigabit Ethernet NIC
    Redundancy: PSU and Fans PSU and Fans
    Ports: 1 serial, minimum 2 USB 1 serial, minimum 2 USB
    Operating System[4], [5]: ARIA (Version 10.0): Windows® Server 2008 R1 (Standard) with Service Pack 2 (25 client access license or sufficient seat licenses) ARIA (Version 10.0): Windows® Server 2008 R1 (Standard) with Service Pack 2 (25 client access license or sufficient seat licenses)
    File System:
    NT File System (NTFS)
    Server
    • Volume C, (OS & APP): 80GB;
    • Volume D, (Database, Database Logs, Database Dumps, & Image Directory): ~1.6TB (RAID 5) @ 15K RPM.
    Server
    • Volume C, (OS & APP): 80GB;
    • Volume D, (Database, Database Logs, Database Dumps, & Image Directory): ~2.2TB (RAID 5) @ 15K RPM.
    Windows® OS Architecture: 64-bit 64-bit
    Microsoft® .NET Framework: ARIA(10.0): 1.1, 2.0, 3.0, and 3.5 ARIA(10.0): 1.1, 2.0, 3.0, and 3.5

    Notes:

    1. Software RAID is neither recommended nor supported with the Duet Server.
    2. Duet Server does not include a tape backup device package.
      a. An optional external tape backup device package can be purchased, which would operate from a separate drive controller.
    3. Hardware used should be approved based on the current Microsoft® Windows® Catalog Listing.
    4. Windows® Server 2008 R2 is currently not compatible with ARIA Version 10.0
    5. Other compatible Windows® operating systems include: Windows Server 2003 and Windows Server 2003 R2, Standard or Enterprise, SP2, 32-bit only.
    6. The Operating System (build and version) of the Duet Server must match the operating system (build and version) of the HARRP target server.
    7. 1 Gbps network recommended for maximum speed and performance.
    8. CPU identified above is for Intel®'s Nehalem or Westmere (microarchitecture). Each CPU has up to three or four separate memory controller hubs (MCHs) within the CPU package, and requires each memory channel to be populated per CPU for optimal use.
    9. Specifications subject to change without notice as newer computer models become available.

     

    Contact Varian Oncology

    Varian Oncology Headquarters
    Tel: 1.650.424.5700
    Contact Us

    EMEA

    Customers in the EMEA region, please check EMEA recommended specifications.

    Events

    Print Normal Bigger Large

    © 1999-2012 Varian Medical Systems, Inc. All rights reserved.
    Production of any of the material contained herein in any format or media without the express written permission of Varian Medical Systems is prohibited.

    Product Index A - Z